m-Fluoroliposome®-DiI (Mannosylated Fluorescent Control Liposomes)

Mannosylated fluorescent liposomes w/ DiI

Mannosylated fluorescent liposomes w/ DiI

More Info
mg/ml mM
L-α-Phosphatidylcholine 18.8 24
Cholesterol 4.2 11
4-Aminophenyl-alpha-D-Mannopyranoside  1  3.69
DiI (lipophilic fluorescent dye: ex/em~550/580 nm) 0.0625 0.065
Suspended in Phosphate Buffered Saline at pH 7.4
  • Prepared identically to Clodrosome (without clodronate; with fluorophore)
  • Required control since phagocytes can respond to liposome uptake
  • May be tracked by fluorescence methods (confocal microscopy, FACS, etc.)
  • Extruded through 2 µm membranes to ensure that liposomes easily pass through lung capillaries
  • Prepared and packaged under sterile conditions

m-Fluoroliposome®-DiO (Mannosylated Fluorescent Control Liposomes)

Mannosylated fluorescent liposomes w/DiO

Mannosylated fluorescent liposomes w/DiO

More Info
mg/ml mM
L-α-Phosphatidylcholine 18.8 24
Cholesterol 4.2 11
4-Aminophenyl-alpha-D-Mannopyranoside  1  3.69
DiO (lipophilic fluorescent dye: ex/em~484/501 nm) 0.0625 0.071
Suspended in Phosphate Buffered Saline at pH 7.4
  • Prepared identically to Clodrosome (without clodronate; with fluorophore)
  • Required control since phagocytes can respond to liposome uptake
  • May be tracked by fluorescence methods (confocal microscopy, FACS, etc.)
  • Extruded through 2 µm membranes to ensure that liposomes easily pass through lung capillaries
  • Prepared and packaged under sterile conditions

m-Fluoroliposome®-DiD (Mannosylated Fluorescent Control Liposomes)

Mannosylated fluorescent liposomes w/DiD

Mannosylated fluorescent liposomes w/DiD

 

More Info
mg/ml mM
L-α-Phosphatidylcholine 18.8 24
Cholesterol 4.2 11
4-Aminophenyl-alpha-D-Mannopyranoside  1  3.69
DiD (lipophilic fluorescent dye: ex/em~748/780 nm) 0.0625 0.065
Suspended in Phosphate Buffered Saline at pH 7.4
  • Prepared identically to Clodrosome (without clodronate; with fluorophore)
  • Required control since phagocytes can respond to liposome uptake
  • May be tracked by fluorescence methods (confocal microscopy, FACS, etc.)
  • Extruded through 2 µm membranes to ensure that liposomes easily pass through lung capillaries
  • Prepared and packaged under sterile conditions

Request Quotation Back to Products
Page 1 of 11

Contact

Encapsula NanoSciences LLC
6 Cadillac Dr
Suite 245
Brentwood, TN 37027
Phone: 1-800-387-0620
Phone: 1-800-401-5140
Fax: 615-250-8747
URL: www.encapsula.com
email: info@encapsula.com

Copyright

Clodrosome®, Encapsome®, and Fluoroliposome® are trademarks of Encapsula NanoSciences. The content of the website can only be used by researchers, educators and students for educational purposes. Any commercial use of the content of the website is legally prohibited by the laws of the United States of America.

Disclaimer

All the products sold on the website are for research purposes only. Any use of these products in humans or animals/ pets for treatment purposes is legally prohibited by U S Food and Drug Administration.